Jockey Pump For Hydrant System
Jockey Pump For Hydrant System
Jockey Pump For Hydrant System
Jockey Pump For Hydrant System

Jockey Pump For Hydrant System

MOQ : 10 Units

Jockey Pump For Hydrant System Specification

  • Control System
  • Automatic with Pressure Switch
  • Speed
  • 2800 RPM
  • Theory
  • Centrifugal Pump
  • Flow Rate
  • Up to 10 m3/hr
  • Head Size
  • Up to 70 meters
  • Caliber
  • 25mm, 32mm, 40mm options
  • Mounting Type
  • Foot Mounted
  • Noise Level
  • <70 dB
  • Max Suction
  • 6-8 meters
  • Frequency
  • 50 Hz
  • Fuel Tank Capacity
  • Not Applicable (Electric Pump)
  • Working Temperature
  • -10C to 80C
  • Features
  • Corrosion Resistant Body, Low Maintenance, High Efficiency
  • Discharge Pressure
  • Up to 12 bar
  • Inlet/Outlet
  • 1 inch / 1 inch (common), customizable
  • Voltage
  • 220V / 380V / 415V AC, 50Hz, 3 Phase
  • Material
  • Cast Iron / Stainless Steel / Bronze
  • Structure
  • Horizontally Mounted, Single Stage
  • Power
  • 0.75 HP to 3 HP
  • Standard
  • IS 9079, IS 9968, NFPA 20, UL/FM
  • Fuel Type
  • Electric (AC Motor Driven)
  • Pressure
  • 5-12 bar (adjustable range)
  • Usage
  • Hydrant Jockey Pumping, Water Replenishment
  • Application
  • Fire Hydrant System Pressure Maintenance
  • Suction Type
  • End Suction
  • Seals Type
  • Mechanical Seal
  • Priming
  • Self / Manual Priming (as per model)
  • Pump Type
  • Close Coupled Centrifugal Pump
  • Capacity
  • 2-10 m3/hr (Model Dependent)
  • Impeller Type
  • Closed, Dynamically Balanced
  • Coupling
  • Flexible Coupling
  • Painting/Coating
  • Anti-Corrosive Industrial Paint
  • Rotation Direction
  • Clockwise (as seen from drive end)
  • Insulation Class
  • Class F
  • Shaft Material
  • SS410 or Equivalent
  • Cooling Method
  • TEFC (Totally Enclosed Fan Cooled)
  • Ambient Temperature Range
  • Up to 50C
  • Protection
  • IP55 Protection Class
  • Recommended Duty Cycle
  • Continuous Operation 24/7
 

Jockey Pump For Hydrant System Trade Information

  • Minimum Order Quantity
  • 10 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Units Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About Jockey Pump For Hydrant System



Order today and capitalise on the trending Jockey Pump for Hydrant System, celebrated for its wondrous efficiency and unprecedented reliability. Featuring a brilliantly designed closed impeller with IP55 protection and dynamically balanced rotation, it delivers continuous 24/7 operation. Built with robust SS410 shafts and anti-corrosive coatings, this pump ensures enduring performance under extreme conditions. Fully customizable, it supports a variety of applications with 1-inch inlets/outlets, multiple caliber options, and flexible coupling for easy installation. Low maintenance, high efficiency, and compliant with IS 9079, IS 9968, and NFPA 20 standards.

Versatile Usage and Distinctive Features

This Jockey Pump is ideal for hydrant system pressure maintenance, water replenishment, and all-around fire safety. Crafted for continuous operation, it features corrosion-resistant materials and an automatic control system with pressure adjustment capabilities. Its compact, horizontally mounted design ensures exceptional energy efficiency, and the low noise level enhances user comfort. Suitable for rigorous environments, this brilliant pump is perfect for commercial, industrial, and residential hydrant setups where reliability is paramount.


Sample Policy and Certifications

Samples of the Jockey Pump for Hydrant System can be handed over upon request, with all units packaged to maintain product integrity. Priced competitively at list rates, selected sample models are available based on basic requirements. Each pump adheres to rigorous certifications, including IS 9079, IS 9968, NFPA 20, and UL/FM (as applicable). Packaging details ensure protection in transit, and documentation accompanies every delivery to verify compliance and performance specifications.


FAQ's of Jockey Pump For Hydrant System:


Q: How does the jockey pump maintain hydrant system pressure?

A: The jockey pump is engineered for continuous 24/7 operation, automatically adjusting to slight pressure drops in the hydrant system. Its control system activates the pump to replenish water and sustain optimal pressure, supporting overall fire safety readiness.

Q: What is the benefit of IP55 protection in this jockey pump?

A: IP55 protection ensures the pump is safeguarded against dust ingress and water jets, making it durable and reliable even in challenging industrial or outdoor settings.

Q: When should a jockey pump be used in a fire hydrant system?

A: A jockey pump should be installed wherever constant system pressure must be maintained, especially in buildings or industrial sites where immediate hydrant activation is critical for fire suppression.

Q: Where can this jockey pump be installed?

A: Its compact, foot-mounted structure allows installation in pump rooms, basements, or dedicated utility areas in residential, commercial, or industrial facilities. The pump is designed to handle ambient and working temperature variations efficiently.

Q: What is the process for requesting a sample?

A: Simply contact the supplier with your basic requirements. Qualified samples can be handed over at list price, and are securely packaged for delivery. Documentation and certifications accompany each sample to affirm quality and compliance.

Q: How does the automatic pressure switch control benefit users?

A: The automatic pressure switch ensures seamless system operation by switching the pump on and off as needed, reducing manual intervention and promoting reliability with minimal maintenance required.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Pumps Category

Horizontal Split Case Fire Pump

Horizontal Split Case Fire Pump

Minimum Order Quantity : 10 Units

Theory : Centrifugal Pump

Pressure : Other, Up to 16 Bar

Seals Type : Mechanical Seal / Gland Packing

Structure : Other, Horizontal Split Case

Speed : 980/1450/2900 rpm

End Suction Electric Fire Pump

End Suction Electric Fire Pump

Minimum Order Quantity : 10 Units

Theory : Centrifugal Pump

Pressure : Other, Up to 16 bar

Seals Type : Mechanical Seal

Structure : Other, Horizontal, End Suction

Speed : 1450 / 2900 rpm

Fire Fighting Terrace Pump

Fire Fighting Terrace Pump

Minimum Order Quantity : 10 Units

Theory : Centrifugal Pump

Pressure : Medium Pressure

Seals Type : Mechanical Seal

Structure : Single Stage Pump

Speed : 2900 RPM



Back to top